Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

  • slide-reefoctopus.gif
  • slide-reef-angel.gif
  • slide-ct-light.gif
  • slide-ocean-nutrition.gif
  • slide-instant-ocean.gif
  • slide-xm.gif
  • slide-skimz.gif
  • slide-solarmax.gif
  • slide-sharkman.gif
  • slide-hailea.gif
  • slide-newlifespectrum.gif
  • slide-wavereef.gif
  • slide-ultralife.gif
  • slide-aquahouse.gif
  • slide-aquapharm.gif
  • slide-injecta.gif
  • slide-prodibio.gif
  • slide-hygger.gif
  • slide-petlife.gif
  • slide-korallen-zucht.gif
  • slide-spectra.gif
  • slide-aqqa.gif
  • slide-aquariuma.gif
  • slide-aquamacro.gif

PDFPrintE-mail
Search by Brand arrow zzz>>>>>>>>>>>>>>>>>>>>>>>>>>>> Jebao arrow Jebao (Dosing Pump) Jecod Auto Dosing Pump DP-4
Jebao (Controller) RW Controller 2019 (24 VDC)Jebao (Food Timer) Automatic Fish Feeder (5000ml)

Jebao (Dosing Pump) Jecod Auto Dosing Pump DP-4
View Full-Size Image


Brand:( Jebao )
Product Name: Jebao (Dosing Pump) Jecod Auto Dosing Pump DP-4
SKU: Jebao Jecod Auto Dosing Pump DP-4
Barcode Link:

Price: Baht 2,800.00
Ask a question about this product

Jebao (Dosing Pump) Jecod Auto Dosing Pump DP-4 Baht 2,800.00



Availability

This product is currently not available.
 

No Guarantee

Jebao ปั๊มจ่ายน้ำยา 4 ช่อง
แต่ละช่องสามารถให้ 1 ถึง 9999มล ต่อครั้ง
แต่ละช่องสามารถตั้งโปรแกรมได้ 24 ครั้งต่อวัน
สามารถเลือกช่วงเวลา 1-30 วันต่อครั้ง
ตั้งค่าเวลาต่างๆ ของเครื่องได้ง่าย
สำหรับ Dosing CA / MG / AB Water หรือของเหลวอื่นๆ
ขนาด 23.5 x 13 x 6.5 ซม
110V ถึง 240V 50 / 60Hz
คำแนะนำการใช้ปั๊ม
Jebao DP-4 เป็นปั๊มที่มีหัวปั๊ม 4 หัวและเหมาะสำหรับการใช้สารเคมีในตู้ปลาเพื่อรักษาระดับแคลเซียมอัลคาลินิตี้แมกนีเซียมและอาหารเสริมอื่น ๆ อีกมากมาย DP-4 มีคอนโทรลเลอร์ในตัวซึ่งช่วยให้ผู้ใช้สามารถกำหนดปริมาณที่ต้องการให้แต่ละหัวปั๊มได้ถึง 30 ครั้งต่อวันต่อปั๊ม คำแนะนำด้านล่างจะนำคุณไปสู่การปรับเทียบการตั้งโปรแกรมและการบำรุงรักษาในปั๊มจ่ายสารใหม่ของคุณ
การตั้งเวลา / วันที่
คุณต้องตั้งเวลาและวันที่ที่เหมาะสมเพื่อให้ปั๊มจ่ายยาใช้เวลาที่ถูกต้องในแต่ละวัน โดยทำตามขั้นตอนด้านล่าง
1) กด OK เพื่อเข้าสู่เมนู ไปที่วันที่ / เวลาและกด OK อีกครั้งเพื่อแก้ไขวันที่
2) เปลี่ยนวันที่โดยใช้ลูกศรขึ้นและลงเพื่อปรับค่าและลูกศรด้านข้างเพื่อสลับจากปีเป็นเดือนหรือวัน กด OK และทำซ้ำขั้นตอนข้างต้นเพื่อแก้ไขเวลา
3) กด OK เพื่อบันทึกวันที่และเวลาจากนั้นกด Esc เพื่อออกจากเมนูหลัก
การสอบเทียบก่อนตั้งโปรแกรม
จำเป็นอย่างยิ่งที่คุณจะต้องปรับเทียบ DP-4 สำหรับหัวปั๊มแต่ละหัวที่คุณต้องการใช้งาน ในการทำเช่นนั้นคุณจะต้องใช้กระบอกฉีดขนาด 100 มล.
1) ในเมนูหลักกดลูกศรด้านข้างเพื่อเข้าสู่โหมดแมนนวลของปั๊ม เลือกปั๊มที่คุณไม่ต้องการเปิดแล้วกดค้างไว้ ไปที่ปั๊มจนกระทั่งน้ำไหลผ่านท่อและออกจากปั๊มที่ปลายด้าน ตรวจสอบให้แน่ใจว่าไม่มีฟองอากาศอยู่ในหลอด
2) กด Esc เพื่อออกจากโหมดปั๊มด้วยตนเองจากนั้นกดลูกศรขึ้นหรือลงเพื่อเข้าสู่โหมดปรับเทียบ
3) ตวงวัด 100mL ของน้ำในกระบอก 100 มล. และใส่สายยางของปั๊มเข้าไปในก้นถัง
4) เลือกปั๊มที่คุณต้องการปรับเทียบโดยกด OK จากนั้นกดลูกศรขึ้นเพื่อเริ่มการปรับเทียบ เมื่อระบาย 100 มล. ทั้งหมดแล้วให้กดลูกศรขึ้นอีกครั้งเพื่อหยุดปั๊ม กด เพื่อบันทึกหมายเลขการปรับเทียบ
5) ทำสิ่งนี้กับปั๊มทุกครั้งที่คุณใช้งานแล้วกด Esc เพื่อออกจากเมนูหลัก
การเขียนโปรแกรม DP-4
ต้องตั้งโปรแกรมปั๊มอย่างถูกต้องเพื่อเพิ่มอาหารเสริมลงในถังในอัตราส่วนที่เหมาะสม ตรวจสอบให้แน่ใจว่าคุณเริ่มต้นด้วยปริมาณที่น้อยมากต่อช่วงเวลาจากนั้นเพิ่มหรือลดปริมาณที่จ่ายหลังจากทดสอบน้ำในตู้ปลาทุกสองสามวันเพื่อให้แน่ใจว่าพารามิเตอร์ของถังของคุณอยู่ในระดับที่เหมาะสม ทำสิ่งนี้จนกว่าคุณจะไปถึงจุดที่สมดุลซึ่งเป็นพารามิเตอร์ที่คุณต้องการให้เป็นและไม่เพิ่มหรือลดลง ถ้าพูดว่าแคลเซียมอยู่ในระดับต่ำคุณจะต้องเพิ่มช่วงเวลาเติม หรือเพิ่มจำนวนต่อช่วงเวลา เพื่อเพิ่มปริมาณ ถ้าแคลเซียมสูงคุณจะทำตรงกันข้าม ตรวจสอบให้แน่ใจว่าเมื่อคุณไปถึงจุดสมดุลคุณจะต้องทดสอบพารามิเตอร์ของคุณเดือนละครั้งเพื่อให้แน่ใจว่าปั๊มที่ใช้งานอยู่ในขนาดที่ถูกต้องสำหรับตู้ปลาของคุณ
1) กดเพื่อเข้าสู่เมนูจากนั้นเลือก "ตั้งโปรแกรม" แล้วกด OK เพื่อเริ่มต้น
2) เลือกปั๊มจ่ายที่คุณต้องการตั้งโปรแกรมแล้วกด OK เพื่อตั้งโปรแกรมกี่ครั้งต่อวันที่คุณต้องการให้ปั๊มทำงาน คุณสามารถเลือกได้ตั้งแต่ 1 ถึง 24 ครั้งต่อวัน เราแนะนำอย่างน้อยวันละ 2 ครั้ง ด้วยวิธีนี้การเติมจะกระทำโดยเพิ่มทีละน้อยซึ่งทำให้พารามิเตอร์ของถังมีเสถียรภาพมากขึ้น
3) เมื่อคุณตั้งค่าจำนวนครั้งที่คุณต้องการให้ปั๊มสูบน้ำทุกวันให้กด OK เพื่อเลื่อนไปยังช่วงวันที่ ปล่อยตัวเลขนั้นไว้ที่ 0 เพื่อให้ปั๊มทำงานทุกวันสำหรับบางอย่างเช่นแคลเซียมหรืออัลคาลินิตี้ 1 เพื่อไปต่อวันเว้นวันหรือมากถึง 30 เพื่อให้ปั๊มทำงานได้เดือนละครั้งสำหรับสิ่งที่ต้องการองค์ประกอบการติดตาม
4) กด OK เพื่อเลื่อนไปยังปริมาณการเติม ตั้งค่าระดับเสียงที่คุณต้องการให้ปั๊มจ่ายจ่ายยาทุกครั้งที่เปิด กด OK เพื่อตั้งเวลาที่คุณต้องการปั๊มสูบจ่ายเพื่อจ่ายสารละลาย
5) ทำซ้ำขั้นตอนที่ 4 สำหรับแต่ละช่วงเวลาการเติม
6) เมื่อคุณตั้งโปรแกรมทุกช่วงเวลาให้กด OK เพื่อออกจากเมนูการเขียนโปรแกรมแล้วกด Esc เพื่อออกจากหน้าจอหลัก
Feature

  • Jebao Brand for 4 Channel Dosing Pump.
  • Each Channel Provides 1 to 9999ml per time.
  • Each Channel can programmable 24 timer per day.
  • Can interval 1-30 days to dosing.
  • Easy Set different time of the Dosing Pump.
  • Idea for Dosing CA / MG / AB Water or other liquid+

Specification

  • Size 23.5 x 13 x 6.5cm
  • Power 110V to 240V 50/60Hz
Jebao DP - 4 Dosing Pump Instructions
Getting Started The Jebao DP - 4 Dosing Pump is a dosing pump with 4 pump heads, and is ideal for dosing chemicals in an aquarium to maintain certain levels of Calcium, Alkalinity, Magnesium, and a myriad of other aquarium supplements. The DP - 4 has a built in controller, which allows the user to set how much they want dosed with each pump head up to 30 times a day, per pump. The instructions below will walk you through calibrating, programming, and maintainin your new dosing pump.
Setting Time/Date
You must set the proper time and date for the dosing pumps to come on at the correct time each day. To do so, follow the steps below.
1) Press ? to enter the menu. Go to Date/Time, and press ? again to edit the date.
2) Change the Date using the Up and Down arrows to adjust the value, and the side arrows to switch from year to month or day. Press ? ag ain and repeat the above steps to edit the time.
3) Press ? to save the Date and Time, then press Esc to exit to the main menu
Calibration Before programming,
it is essential that you calibrate the DP - 4 for each pump head you intend to utilize. To do so, you will need a 100ml graduated cylinder and RO/DI or distilled water.
1) On the main menu, press either side arrow to access the pump's manual mode. Select the pump you wa nt to turn on, and press and hold ? to r u n the pump until water runs through the tube and out of the pump on the o ther end. Make sure that no air bubbles are present in the tubing.
2) Press Esc to exit the manual pump mode, then press either up or down arrow to enter calibration mode.
3) Measure out 100mL of RO/DI water or distilled water in a 100mL graduated cylinder, and insert the pump's input hose into the bottom of the cylinder.
4) Select the pump you want to calibrate by pressing ? , then press the up arrow to begin calibration. Once all 100 mL has been drained, press the up arrow again to stop the pump. Press ? to save the calibration number.
5) Do this for every pump you in tend to use, then press Esc to exit to the main menu.
Programming the DP - 4
The dosing pump must be programmed correctly to add supplements to the tank in the proper ratios. Make sure th at you start out with very little dosing per time interval, then increase or decrease the amount dosed after testing the aquarium water every few days to ensure the parameters of your tank are at the proper level. Do this until you have reached equilibrium, where the parameters are where you want them to be, and not increasing or decreasing. If, say, calcium is low, you would add mor e intervals or more mL per interval to increase the dosage . If Calcium was high, you would do the opposite . Make sure that once you reach equilibrium, you test your parameters once a month to ensure the doing pump is putting in the correct dose for your tank, and adjust it a ccordingly.
1) Press _ to enter the menu, then select " Set Program " and press _ to get started.
2) Select the dosing pump you would like to program, and press _ to program how many times per day you want the pump to come on. You can choose anywhere from 1 to 24 times per day. We recommend at least 2 times per day. That way, the dosing is done in small er increments, which makes the tank parameters more stable.
3) Once you set the amount of times you want the pump to come on daily, press _ to move on to t he day interval. Leave that number at 0 for the pump to run every day for something like Calcium or Alkalinity , 1 to go on every other day, or up to 30 for it to come on only once a month, for something like trace elements.
4) Press _ ag ain to move on to the dosing volume. Set the volume you would like the dosing pump to dispense each time it comes on. Press _ to set the time you would like the dosing pump to dispense that amount of solution.
5) Repeat step 4 for each dosing interval.
6) When you have programmed every interval, press _ to exit to the programming menu, then Esc. To exit to the main screen.

Aqua Medic Check Valve 6mm
No Name Silicone Tube 6mm (1/4 inc)




Number pieces in packaging:1
Number pieces in box:6


Customer Reviews:

There are yet no reviews for this product.
Please log in to write a review.




You may also be interested in this/these product(s)


Notice: Undefined variable: relItem in /home/seasunaq/domains/seasunaquarium.com/public_html/shop/components/com_virtuemart/themes/default/templates/common/relatedProducts.tpl.php on line 10

Notice: Undefined variable: relItem in /home/seasunaq/domains/seasunaquarium.com/public_html/shop/components/com_virtuemart/themes/default/templates/common/relatedProducts.tpl.php on line 25