SeaSun (Controller) Digital Temp Control STC-3008 (2200w/10A)SeaSun (Controller) Digital Temp Controller AC112 (2000w/10A)
View Full-Size Image
|
Brand:( SeaSun )
Product Name: SeaSun (Controller) Digital Temp Control STC-8080A+ (1500w/7A)
SKU: SeaSun Digital Temp Control STC-8080A+ (1500w/7A)
Barcode Link:
|
|
|
|
|
In Stock:
12
|
|
STC-8080A + Microcomputer Temperature Controller Instruction Manual technical parameter 1. Power supply:110-220VAC +10%-15%,50 / 60Hz 2. Machine power consumption <3w 3. Measuring range:-50°C to 99°C 4. Temperature control range:-40°C-50°C 5. Temperature resolution:1°C 6. Sensor type:NTC sensor 7. Measurement accuracy:40°C-50°C is 1°C,the rest is 8. Front panel protection level:IP64 9. Refrigeration output contact capacity:7A at 220VAC / 14A at 110VAC 10. Defrost output contact capacity:7A at 220VAC / 14A at 110VAC 11. Working environment temperature:0°C-60°C 12. Storage temperature:-30°C-75°C 13. Working environment humidity:20-85%(no condensation)
View parameter settings Press and immediately release the ^ button to display the set temperature upper limit,press and immediately release the v button to display the set temperature lower limit : Press and immediately release the RST button to display the set defrost cycle : Press and immediately release the RST key to display the set defrosting time. After 2 seconds,it returns to the normal temperature display state
Modify parameter setting value Press the SET key for more than 3 seconds to enter the parameter modification mode,the last adjusted menu item after power-on is displayed,and the colleague parameter modification mode indicator light is on. Press the ^ key or the v key to scroll up or down the menu item,and press the SET key to display the parameter setting value of the current menu. Press and hold the SET key,and then press the ^ key or v key to adjust the parameter setting value of the current menu. At the same time,press and hold the SET key and ^ key for more than one second to quickly increase the parameter setting value of the current menu. Hold down the SET key and the v key for more than one second to quickly lower the current menu parameter setting value. Press and hold the SET button or there is no button operation within 30 seconds to save the parameter modification and return to the normal temperature display state.
Manual defrost Manual defrosting function is allowed when the set value of defrosting time is not 0. Non-defrosting time Press and hold the v key for more than 3 seconds to start manual defrosting. When defrosting,press and hold the v key for more than 3 seconds to stop defrosting manually.
Restore parameter settings When the machine is powered on,first check whether the parameter settings are correct. If an error is detected. E1 will be displayed and the buzzer will sound. Press the SET key at this time to restore the default parameter settings and work normally,it is recommended to reset the parameters at this time
Control output compressor When the storage temperature is higher than the upper limit of the set temperature,the compressor will be turned on,and when the temperature is lower than the lower limit of the set temperature, the compressor will be turned off. After the storage temperature sensor fails,the compressor will run at a ratio of 15 minutes to 30 minutes, Compressor that runs for 3 minutes after shutdown. The protection time allows the compressor to start again.
Transform When the machine has completed the set defrosting cycle or when the machine is not defrosting, Press and hold the v key for more than 3 seconds to start defrosting. During the defrosting period,refrigeration output is prohibited. Defrost,restart the defrost cycle after the machine is energized or after the defrost is over. When either the defrost cycle or defrost time is set to 0,the timing defrost function is can celled,but manual defrost is allowed when the defrost time is not 0.
Frost Call the police When the temperature overrun deviation is not 0,the storage temperature is higher than the set temperature upper limit + temperature overrun deviation or lower than set temperature lower limit-temperature overrun alarm occurs when the temperature overrun deviation,and the current temperature is flashing and displayed. The buzzer sounds and the alarm is released when the temperature drops to the normal temperature range. E1 flashes and the buzzer sounds when the memory is faulty,E2 flashes and the buzzer sounds when the sensor is faulty,and the storage temperature is higher than 99 C. And it shows HH when it is lower than 120 C. When alarming,press any key to manually silence the sound,but the alarm display state will not be changed.
Menu description
Menu logo |
Menu function |
Predetermined area |
Unit |
Defaults |
Setting Recommended |
|
|
|
|
|
Aquarium |
Reptile |
Ozoner |
UPS |
F1 |
Upper temperature limit |
F2 to 50 |
oC |
-10 |
26 |
32 |
50 |
50 |
F2 |
Lower temperature limit |
-40 to F1 |
oC |
-20 |
25 |
28 |
0 |
0 |
F3 |
Temperature correction |
-5 to +5 |
oC |
0 |
0 |
0 |
0 |
0 |
F4 |
Deforst cycle |
0-99 |
hour |
8 |
0 |
0 |
1 |
20 |
F5 |
Defort time |
0-99 |
minute |
20 |
0 |
0 |
***F5 |
30 |
F6 |
Temperature overrun deviation |
0-99 |
oC |
15 |
5 |
5 |
20 |
20 |
***F5 คำนวนได้ดังนี้ A ปริมาณน้ำในตู้ปลา B ปริมาณโอโซน ดูที่เครื่อง (mg) A / B x 12 = ***F5 เช่น ตู้ 500 ลิตร ใช้ เครื่องโอโซน 1000มก. 500 / 1000 x 12 = 6
NOTE : เมื่อ F5 (socket 5) ทำงาน ระบจะเปลี่ยนการทำงาน F1 (socket 10) เป็น F2 (socket 8) ทันที / เมื่อ F5 (socket 5) หยุดทำงาน F4 (socket 7) ทำงาน ระบบ F1 (socket 10) และ F2 (socket 8) จะเข้าสู่ระบบอัตโนมัติปกติ
Safety rules: 1. Strictly distinguish the sensor lead,power cord and output relay interface,do not connect wrongly,and the relay must not be overloaded. 2. All wiring changes must be made with the power supply disconnected
Caveat: 1. This machine is forbidden to be used in water or excessively humid environments,and it is forbidden to use it in high temperature,strong electromagnetic interference,and strong corrosive environments.
Note: 1. The supply voltage should be consistent with the machine's marked voltage,and the stability of the supply voltage should be guaranteed. 2. In order to avoid possible introduction of interference,it is recommended to keep a proper distance between the sensor lead and the power.
Fault code, reason and action
Error code |
Cause of issue |
Action |
LL |
Low temperature Alam |
Setting F6 too low or sensor near expire or Heater is not working
|
E2 |
Storage temperature sensor failure |
Alarm compressor proportional start and stop |
HH |
temperature is out of display range |
Setting F6 too low or sensor near expire or Heater is not working |
Indicator light |
State |
Features |
SUN picture |
ON |
F5 (Socket 5) output |
SUN picture |
OFF |
F4 (Socket 7) output |
SNOW picture |
ON |
F1 (Socket 8) output |
SNOW picture |
Flashing |
F1 (Socket 8) output delay 3 mins |
SNOW picture |
OFF |
F2 (Socket 10) output |
THEMPERATURE |
Flashing |
F6 Warning (MIN/MAX) |
|
|
Number pieces in packaging:1 Number pieces in box:12 |
|